GFCI vs AFCI Requirement Checker

Determine where GFCI protection (§210.8) and AFCI protection (§210.12) are required by room, location, voltage, and occupancy type (dwelling vs commercial) under NEC 2026/2023.

NEC edition

Inputs

VoltageLab app

Take this toolkit with you on the job

The full VoltageLab electrician app — wire tables, code lookups and job-site calculators offline, on Android and iOS.

How it works & the NEC rules behind it

The National Electrical Code mandates two distinct types of personnel and property protection devices that operate on different principles:

  • GFCI (Ground-Fault Circuit-Interrupter — §210.8): Protects humans from lethal electric shock and electrocution by sensing imbalances between hot and neutral currents as low as 4 to 6 milliamperes (mA) within milliseconds.
  • AFCI (Arc-Fault Circuit-Interrupter — §210.12): Protects structures from electrical fires by detecting dangerous electrical arcing (sparking from frayed cords, punctured Romex, loose wire terminals) that standard thermal-magnetic breakers ignore.
  • Dual-Function (DFCI / AFCI+GFCI): Combines both arc-fault and ground-fault protection in a single circuit breaker or receptacle device.

NEC reference table

Dwelling Unit Location GFCI Required? (§210.8(A)) AFCI Required? (§210.12(A)) Protection Device Recommendation
Kitchen Countertops✓ YES✓ YESDual-Function (AFCI + GFCI)
Bathrooms✓ YES✓ YESDual-Function or GFCI Receptacle + AFCI Breaker
Garages & Accessory Buildings✓ YES✓ YESDual-Function
Outdoors & Damp/Wet Areas✓ YESNo (unless branch origin in dwelling)Weather-Resistant GFCI Receptacle
Unfinished Basements & Crawl Spaces✓ YES✓ YESDual-Function
Bedrooms & Living RoomsNo (unless within 6ft of sink)✓ YESStandard AFCI Breaker
Laundry Areas✓ YES✓ YESDual-Function
EVSE / Garage EV Outlets✓ YES (§625)No (unless 120V 15/20A)GFCI Breaker

Worked example, step by step

Example Scenario: Kitchen Remodel Wiring Requirements

Scenario: You are adding two 20A small appliance branch circuits for kitchen countertops and a dedicated 120V circuit for a garbage disposal and dishwasher.

  • Kitchen Countertop Receptacles: Required to have both GFCI (§210.8(A)(6)) and AFCI (§210.12(A)). Solution: Install 20A Dual-Function AFCI/GFCI circuit breakers.
  • Dishwasher: Required to have GFCI (§210.8(D)) and AFCI (§210.12(A)). Solution: Dedicated 15A/20A Dual-Function breaker.

Frequently asked questions

No. Standard GFCI outlets only detect ground faults (current leaking to ground) and do not detect series or parallel arc faults. To satisfy both requirements, you must either install a combination Dual-Function (AFCI+GFCI) breaker/outlet or an AFCI circuit breaker upstream of a GFCI receptacle.

Under NEC 2020, 2023, and 2026 §210.8(A) & §210.8(F), GFCI protection is required for all outdoor outlets up to 50A (including mini-split heat pumps and central AC units), and appliances in laundry/kitchen areas supplied by single-phase branch circuits rated 150V to ground or less (e.g. 120/240V dryers and ovens).